Spa Extreme Novec FIA Fire System 4.0kg
$1,526.00
SPA Technique Extreme Novec FIA Fire System 4.0kg
The SPA Technique EX 4.0 is the lightweight, electrically-discharged fire system using 3M Novec 1230 agent that meets the FIA EX.029.09 rating. This system keeps weight to a minimum for the lightest-weight race cars that still need the ultimate in fire protection.
This SPA Technique Extreme Novec 1230 4.0kg FIA EX029.09 certified fire system represents the next generation of race car fire suppression. Innovative 3M Novec 1230 suppressant is not only safer for your driver, but also easier on the environment. All while being non-conductive (so, safe for electronics) and leaving no residue to clean up. If you want the safest FIA-rated race car fire system, this SPA Technique Novec 1230 Extreme system is your first choice.
Easy Installation with the Included System Kit
Installation of your SPA Technique 4.0kg system is easy because this kit includes everything you need for a easy and safe installation. A completely filled FIA EX.0239.09 certified and labeled bottle is included, as are the two stainless steel retaining straps. For discharge, two simple-to-connect electrical discharge switches are included: one usually mounted externally on the cowl and the other in the cockpit near the driver. The cabling is long enough to mount the lightweight aluminum bottle where the driver and crew chief want it. This complete fire system also includes four nozzles, three T-fittings, one bulkhead fitting, and 10 feet of easy-to-install tubing. There is even a new "E" decal to make even the grumpiest tech chief happy.
SPA Technique Novec fire systems are the perfect choice for drivers who need the best in FIA EX.029.09 certified fire safety.
This pressurized fire system can only be shipped via Ground.
SPA Technique Extreme Novec FIA Fire System 4.0kg Details:
Manufacturer: SPA Technique
Manufacturer part number: EX02909
Discharge 1: Electrical External
Discharge 2: Electrical Internal
Certification: FIA EX.029.09
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
SPA Technique Extreme Novec FIA Fire System 4.0kg Benefits:
Advanced 3M Novec 1230 fluid is safer and cleaner than other agents
Great fire-out properties
Non-toxic, so safe for driver
Non-conductive, safe on all electronics
No residue to clean-up
Zero ozone depletion, making it safer for the environment
SPA Technique Installation Kit Includes:
Fully charged Novec 1230 bottle
Four nozzles
Three T-fittings
One bulkhead fitting
Two stainless steel mounting straps
Ten feet of system tubing
Electrical activation kit with two switches
"E" sticker
SPA Technique
Spa Extreme Novec SFI Fire System 10lb - 3-Way Firing Head
$1,522.00
Spa Extreme Novec SFI Fire System 10lb With 3-Way Firing Head
Why the SPA Technique three-way firing head? Safety. This extraordinary fire system can be discharged manually using the pull cable or electric push button. Or it will fire automatically at 155º F, thanks to a specially designed frangible bulb that discharges your fire system in the event of an unconscious driver.
SPA Technique Extreme Novec 1230 10lb SFI 17.1 certified fire system is the next generation of race car fire suppression. The new 3M Novec 1230 is not only safer for your driver, but also for the environment. All while being non-conductive (i.e., safe for electronics) and leaving no residue. If you want the safest, most fool-proof race car fire system, the SPA Technique Novec 1230 Extreme system with the three-way firing head is your first choice.
Easy Installation with the Complete Kit
Installation of your SPA Technique 10lb SFI 17.1 system is easy with this kit including everything you need for a easy and safe installation. A completely filled SFI 17.1 certified and labeled bottle is included, along with two stainless steel retaining straps. For discharge, the single six-foot pull cable is typically long enough to allow location of the bottle where the you and your crew chief want it. This complete fire system includes four nozzles, three T-fittings, one bulkhead fitting, and 10 feet of 5/16" easy-to-install aluminum tubing. There is also a new "E" decal to complete your installation.
SPA Technique fire systems are the perfect choice for drivers who want the best in SFI 17.1 certified fire safety.
This pressurized fire system can only ship via Ground.
Spa Extreme Novec SFI Fire System 10lb Three-Way Head Details:
Manufacturer: SPA Technique
Manufacturer part number: EX-SFI5-3W
Discharge 1: Pull-Cable
Discharge 2: Push-Button
Discharge 3: Automatic at 155º F (68º C)
Certification: SFI 17.1
Suppression Agent: 3M Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
Spa Extreme Novec SFI Fire System Contents:
Fully Charged Novec 1230 Bottle w/ 3-Way Head
Retaining Straps x 2
Pull Cable, six feet
Discharge Nozzles x 4
T-Fittings x 3
Bulkhead Fitting
5/16" Aluminum Tubing, 10 feet
E-Sticker
SPA Technique
Spa Extreme Novec SFI Fire System 5lb - 3-Way Firing Head
$1,215.00
Spa Extreme Novec SFI Fire System 5lb with Three-Way Firing Head
Why the SPA Technique three-way firing head? Safety. This extraordinary fire system can be discharged manually using the pull cable or electric push button. Or it will fire automatically at 155º F, thanks to a specially designed frangible bulb that discharges your fire system in the event of an unconscious driver.
SPA Technique Extreme Novec 1230 5lb SFI 17.1 certified fire system is the next generation of race car fire suppression. The new 3M Novec 1230 is not only safer for your driver, but also for the environment. All while being non-conductive (i.e., safe for electronics) and leaving no residue. If you want the safest, most fool-proof race car fire system, the SPA Technique Novec 1230 Extreme system with the three-way firing head is your first choice.
Easy Installation with the Complete Kit
Installation of your SPA Technique 5lb SFI 17.1 system is easy with this kit including everything you need for a easy and safe installation. A completely filled SFI 17.1 certified and labeled bottle is included, along with two stainless steel retaining straps. For discharge, the single six-foot pull cable is typically long enough to allow location of the bottle where the you and your crew chief want it. This complete fire system includes two nozzles, one T-fittings, one bulkhead fitting, and 10 feet of 5/16" easy-to-install aluminum tubing. There is also a new "E" decal to complete your installation.
SPA Technique fire systems are the perfect choice for drivers who want the best in SFI 17.1 certified fire safety.
This pressurized fire system can only ship via Ground.
Spa Extreme Novec SFI Fire System 5lb Three-Way Head Details:
Manufacturer: SPA Technique
Manufacturer part number: EX-SFI5-3W
Discharge 1: Pull-Cable
Discharge 2: Push-Button
Discharge 3: Automatic at 155º F (68º C)
Certification: SFI 17.1
Suppression Agent: 3M Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
Spa Extreme Novec SFI Fire System Contents:
Fully Charged Novec 1230 Bottle w/ 3-Way Head
Retaining Straps x 2
Pull Cable, six feet
Discharge Nozzles x 2
T-Fitting
Bulkhead Fitting
5/16" Aluminum Tubing, 10 feet
E-Sticker
SPA Technique
Spa Extreme Novec SFI Fire System 10lb - Machined Head
$1,022.00
Spa Extreme Novec SFI Fire System 10lb - Machined Head
This "Machined Head" SPA Technique fire system uses an internal firing mechanism to make the bottle as small as possible, without going to the extra expense of an electrically discharged race car fire system. Space is always at a premium in a race car, so the master engineers at SPA Technique listened to the many, many crew chiefs that want the quality and reliability of SPA Technique, but in a cost effective, compact fire system.
SPA Technique Extreme Novec 1230 10LB SFI 17.1 certified fire system is the next generation of race car fire suppression. The new 3M Novec 1230 is not only safer for your driver, but also for our environment! All while being non-conductive (i.e., safe for electronics) and leaving no residue to clean up. If you want the safest race car fire system, SPA Technique's Novec 1230 Extreme systems are your first choice.
Installation of your SPA Technique 10LB SFI 17.1 system is easy because this kit includes everything you will need for a easy and safe installation. A completely filled SFI 17.1 certified and labeled bottle is included, as are the two stainless steel retaining straps. For discharge, the single six-foot pull cable is usually more than long enough to place the bottle where the driver and crew chief want it. This complete fire system also includes four nozzles, three T-fittings, one bulkhead fitting, and ten feet of 5/16" easy-to-install aluminum tubing. There is even a new "E" decal to make the grumpiest tech chief happy.
SPA Technique fire systems are the perfect choice for drivers that want the best in SFI 17.1 certified fire safety.
This fire system is pressurized and can only be shipped via Ground.
SPA Extreme Novec SFI Fire System 10lb Machined Head Details:
Manufacturer: SPA Technique
Manufacturer part number: EX-SFI10-M
Certification: SFI 17.1
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
SPA Extreme Novec SFI Fire System 10lb Machined Head Contents:
Fully charged Novec 10-lb. bottle with Machined Head
Retaining Straps x 2
Pull Cable, six feet
Discharge Nozzles x 4
T-Fittings x 3
Bulkhead Fitting
5/16" Aluminum Tubing, 10 feet
E-Sticker
SPA Technique
Spa FireSense SFI 17.1 Fire System 10lb. Auto-Manual Discharge
from $979.00
SPA FireSense SFI 17.1 Fire System 10lb. Auto/Manual Discharge
The SPA Technique SFI 17.1 Fire System is a full 10 lbs. of powerful FireAde 2000 foam agent. What makes this SPA Technique system most impressive is that in addition to the manual lanyard used for manual discharge, there is also a 175º F (65º C) automatic discharge feature.
The SPA FS-SFI10AM-F-2 Auto/Manual Discharge system is SFI 17.1 Certified and exceeds the requirements for fire suppression in place for the unified Dirt Late Model and Dirt Modified rules.
This pressurized fire system can only be shipped via Ground.
SPA Extreme Novec SFI 17.1 Fire System Details:
Manufacturer: SPA Technique
Manufacturer part number: FS-SFI10AM-F-2
Discharge 1: Manually via mechanical lanyard
Discharge 2: Automatic at 175º F (65º C)
Certification: SFI 17.1
Agent: FireAde 2000
Toxic: No
Bottle dimensions: 21.5" H x 5.25" DIA
SPA Extreme Novec SFI 17.1 Fire System Includes:
Lightweight aluminum bottle pre-charged with 10lbs. of FireAde 2000 foam agent
Remote Mounting Block with thermal bulb (175º F is standard; higher temps are available)
Manual activation lanyard (pull cable optional)
Four nozzles for coverage of driver, engine bay and/or fuel cell
Two T-fittings
One bulkhead fitting
12.5 feet of bendable steel tubing with easy to use push-lock fittings
Stainless T-bolt panel mounting clamps included
Optional: Billet bottle mounting clamps (pair)
SPA Technique
SPA AFFF Fire System 4 Liter Alloy Electric & Auto Discharge
$963.00
SPA AFFF Fire System 4 Liter Alloy Electric & Auto Discharge
SPA Technique Designed Firefighter System
This SPA Technique 4 Liter AFFF Fire System offers dual push-button electric discharge actuators, one mounted near the driver and the other mounted externally for emergency workers. In addition, it offers automatic discharge at a temperature of 175º F. The four discharge nozzles make sure both driver and race car survive to race another day.This SPA Technique 4L system is specifically designed for use in competition vehicles, offering the latest in on board fire suppression technology. Utilizing SPA "Lite" AFFF (Aqueous Film Forming Foam), this non-toxic, ozone friendly system gives any competitor the same level of protection as professional race teams use.
FIA Rated for the Ultimate in In-Car Fire Protection
The lightweight alloy 4 Liter FireSense bottle carries FIA homologation number EX.045.17.d. SPA Technique's Multi-Flo AFFF fire systems are designed specifically for closed-cockpit cars (e.g., touring or rally cars). With the six nozzles and a large four-liter bottle, splitting fire protection between the engine compartment and cockpit has never been simpler! Dual electric actuation switches insure instant activation.
SPA AFFF Fire System 4 Liter Alloy Electric & Auto Discharge Details:
Manufacturer: Spa Technique
Manufacturer part number: FIA-18-E-4A
Rating: FIA # EX.045.17
Diameter: 5.9"
Overall Length: 14.94"
SPA AFFF Fire System 4 Liter Alloy Electric & Auto Discharge Contents:
AFFF Nozzles (2 engine, 2 cockpit)
10mm to 8mm Y-fitting
8mm T-fittings (2)
8mm bulkhead fitting
10mm Dekabon tubing (20in/0.5 meter)
8mm Dekabon tubing (14.75 feet/4.5 meters)
Bottle mounts with FIA anti-torpedo tabs (2)
Large E sticker
Small E sticker
One power pack
Plugs and leads (2)
Internal push-button
External push-button (waterproof)
SPA Technique
SPA Extreme Novec SFI Fire System 10lb
$872.00
SPA Extreme Novec SFI Fire System 10lb
The SPA Technique Extreme Novec 1230 10lb SFI 17.1 certified fire system is the next generation of race car fire suppression. The new 3M Novec 1230 is not only safer for the driver, but also for the environment. All the while being non-conductive (i.e., safe for electronics) and leaving no residue. If you want the safest race car fire system, the SPA Technique Novec 1230 Extreme systems are your first choice.
Installation of your SPA Technique 10lb SFI 17.1 system is easy because the kit includes everything you will need for an easy and safe installation. A completely filled SFI 17.1 certified and labeled bottle is included, as are two stainless steel retaining straps. For discharge, the single six-foot pull cable is typically more than long enough to locate the bottle where the driver and crew chief want it. This complete fire system also includes four nozzles, three T-fittings, one bulkhead fitting, and ten feet of 5/16" easy-to-install aluminum tubing. There is even a new "E" decal to make the grumpiest tech chief happy.
SPA Technique fire systems are the perfect choice for drivers who want the best in SFI 17.1 certified fire safety.
This pressurized fire system can only be shipped via Ground.
Spa Extreme Novec SFI Fire System 10lb Details:
Manufacturer: SPA Technique
Manufacturer part number: EX-SFI10
Certification: SFI 17.1
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
Bottle Height: 17.75"
Bottle Dia: 5.25"
Spa Extreme Novec SFI Fire System Kit Contents:
Ten-pound bottle, fully charged
Retaining Straps x 2
Pull Cable, six feet
Discharge Nozzles x 4
T-Fittings x 3
Bulkhead Fitting
5/16" Aluminum Tubing, ten feet
E-Sticker
SPA Technique
SPA Technique AFFF Fire System - 2.25 Liter Electric - LWE50
$730.00
SPA Technique AFFF Fire System - 2.25 Liter Electric
SKU: LWE50
Spa Technique's Firesense Single Chamber AFFF Fire Systems feature dual push-button electronic actuators. The dual-nozzle system is the perfect level of protection for the cockpit or engine compartment. SPA "Lite" AFFF (Aqueous Film Forming Foam) is a non-toxic, ozone friendly, fire suppressant that offers the competitor the same level of protection as the pros use. Lightweight alloy 2.25 Liter Firesense bottle features a compact size perfect for smaller, open wheel racers.
FIA Homologation # EX.003.98 - does not meet current FIA 2018 homologation needs.
*Must ship via ground*
SPA Technique
Spa Extreme Novec SFI 17.1 Fire System 5lb - Machined Head
$715.00
Spa Extreme Novec SFI Fire System 5lb - Machined Head
This "Machined Head" SPA Technique fire system uses an internal firing mechanism to make the bottle as small as possible, without going to the extra expense of an electrically discharged race car fire system. Space is always at a premium in a race car, so the master engineers at SPA Technique listened to the many, many crew chiefs that want the quality and reliability of SPA Technique, but in a cost effective, compact fire system.
SPA Extreme Novec SFI Fire System 5lb Machined Head Details:
Manufacturer: SPA Technique
Manufacturer part number: EX-SFI5-M
Certification: SFI 17.1
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
Height: 13.0"
Diameter: 4.25"
SPA Extreme Novec SFI Fire System 5lb Machined Head Contents:
Fully-charged 5-lb. Novec bottle with Machined Head
Retaining Straps x 2
Pull Cable, six feet
Discharge Nozzles x 2
T-Fitting
Bulkhead Fitting
5/16" Aluminum Tubing, 10 feet
E-Sticker
The SPA Technique Extreme Novec 1230 5LB SFI 17.1 certified fire system is the next generation of race car fire suppression. This new 3M Novec 1230 is not only safer for you, but also for the Earth. All while being non-conductive (i.e., safe for electronics) and leaving no residue. If you want the safest race car fire system, the SPA Technique Novec 1230 Extreme systems are your first choice.
Installation of your SPA Technique 5LB SFI 17.1 system is easy because the kit includes everything you'll need for a safe, easy installation. A completely filled SFI 17.1 certified and labeled bottle is included, as are the two stainless steel retaining straps. For discharge, a six-foot pull cable is included, typically more than enough to locate the bottle where you and crew chief want it. This complete fire system also includes two nozzles, one T-fitting, one bulkhead fitting, and ten feet of 5/16" easy-to-install aluminum tubing. There is even a new "E" decal to make the grumpiest tech inspector happy.
SPA Technique fire systems are the perfect choice for drivers that want the best in SFI 17.1 certified fire safety.
SPA Technique fire systems are pressurized and can only be shipped via Ground.
SPA Technique
SPA Extreme Novec SFI 17.1 Fire System 5lb. Light Weight
$678.00
SP Extreme Novec SFI 17.1 Fire System 5lb. Light Weight Mechanical
The SPA Technique EX SFI5-LW bottle weighs only 6.7 lbs. filled and ready to use. Filled with lightweight Novec 1230 suppression agent, this mechanically discharged fire system not only carries an SFI 17.1 rating, but it keeps weight to an absolute minimum for lightweight race cars that still need the ultimate in fire protection.
The SPA Technique Extreme Novec 1230 5lb. SFI 17.1 certified fire system is the next generation of light weight race car fire suppression. The new 3M Novec 1230 is not only safer for the driver, but also the Earth. All while being non-conductive (i.e., safe for electronics) and leaving no residue. If you want the safest race car fire system, the SPA Technique Novec 1230 Extreme systems are your first choice.
Installation of your SPA Technique 5lb. SFI 17.1 system is easy because your kit includes everything you will need for a easy and safe installation. A completely filled light weight SFI 17.1 certified and labeled bottle is included, as are the two stainless steel retaining straps. For discharge, two simple-to-connect electrical discharge switches are included. One is usually mounted externally on the cowl and the other in the cockpit near the driver.
The cabling is long enough to mount the lightweight aluminum bottle where you and your crew chief want it. This complete fire system includes four nozzles, three T-fittings, one bulkhead fitting, and ten feet of easy-to-install tubing. There is even a new "E" decal to make the grumpiest tech chief happy.
SPA Technique fire systems are the perfect choice for drivers that want the best in light weight SFI 17.1 certified fire safety.
This pressurized SPA Technique fire system can only be shipped via Ground.
SPA Extreme Novec SFI 17.1 Fire System 5lb. Light Weight Mechanical Details:
Manufacturer: SPA Technique
Manufacturer part number: EX2SFI5-LW
Discharge 1: Mechanical cable 6'
Discharge 2: Mechanical cable 12'
Certification: SFI 17.1
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
SPA Extreme Novec SFI 17.1 Fire System 5lb. Light Weight Mechanical Contents:
Two Discharge Nozzles
Ten Feet of Lightweight Tubing
One T-fitting
One Bulkhead fitting
One 12-foot Pull Cable
Two E-stickers (one large, one small)
Two Bottle Mounts
Two Anti-Torpedo Brackets
SPA Extreme Novec SFI 17.1 Fire System Benefits:
A few of the advantages of using NovecTM 1230 Fluid in place of other fire-suppression agents are as follows:
Great fire-out properties
Non-toxic, so safe for driver
Non-conductive, so it's safe on all electronics
No residue or clean-up
Zero ozone depletion, making it safer for the environment
SPA Technique
SPA Extreme Novec FIA Fire System 2.25kg Mechanical
$675.00
SPA Extreme Novec FIA Fire System 2.25kg Mechanical
This SPA Technique Extreme 2.25kg Novec Fire System (SPAEX 2.25-M) is a lightweight, mechanically-discharged fire system using Novec 1230 agent that not only meets the FIA EX.049.18 rating, but keeps weight to a minimum for the lightest of race cars that need the ultimate in protection.
SPA Technique Extreme Novec 1230 2.25kg FIA EX049.18 certified fire system is the next generation of race car fire suppression. The new 3M Novec 1230 is not only safer for your driver, but also the Earth all the while being non-conductive (safe for electronics), and leaves no residue. If you want the safest race car fire system, the SPA Technique Novec 1230 Extreme systems are your first choice.
Installation of your SPA Technique 2.25kg system is easy because your kit includes everything you will need for a easy and safe installation. A completely filled, FIA EX.049.18 certified and labeled bottle is included, as are two stainless steel retaining straps. For discharge, two mechanical pull-cables are included: one is usually mounted externally on the cowl and the other within reach of the driver. The cabling is long enough to mount the lightweight aluminum bottle where you and your crew chief want it. This complete fire system also includes three nozzles, two Y-fittings, one bulkhead fitting, and 10 feet of easy-to-install tubing. There are two a new "E" decals so corner workers know exactly where to find the actuator handles.
SPA Technique fire systems are the perfect choice for drivers who insist on the best in FIA-certified fire safety.
This pressurized fire system can only be shipped via Ground.
SPA Extreme Novec FIA Fire System 2.25kg Mechanical Details:
Manufacturer: SPA Technique
Manufacturer part number: EX2.25-M
Discharge 1: Mechanical cable 6 ft
Discharge 2: Mechanical cable 12 ft
Certification:
FIA EX.049.18
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
SPA Extreme Novec FIA Fire System 2.25kg Mechanical Contents:
(1) Cockpit deflector nozzle
(2) Engine bay nozzles
0.5M of 12mm Dekabon tubing
2.5M of 10mm Dekabon tubing
4.5M of 8mm Dekabon tubing
(1) 12mm to 10mm Y-fitting
(1) 10mm to 8mm Y-fitting
(1) 10mm to 8mm reducer fitting
(1) 10mm bulkhead fitting
(1) 6 ft pull cable
(1) 12 ft pull cable
(2) E-stickers (one large, one small)
(2) Bottle mounts
(2) FIA anti-torpedo brackets
Advantages of the Novec 1230 Fluid:
Great fire-out properties
Non-toxic, so it's safe for driver, crew, safety workers
Non-conductive, so it's safe on all electronics
No residue or clean-up
Zero ozone depletion, making it safer on the environment
SPA Technique
SPA Extreme Novec SFI Fire System 5lb
$563.00
SPA Extreme Novec SFI Fire System 5lb
The SPA Technique Extreme Novec 1230 5lb SFI 17.1 certified fire system is the next generation of race car fire suppression. The new 3M Novec 1230 is not only safer for the driver, but the Earth as well! All the while being non-conductive (i.e., safe for electronics) and requiring no residue clean-up. If you want the safest race car fire system, the SPA Technique Novec 1230 Extreme systems are your first choice.
Installation of your SPA Technique 5lb SFI 17.1 system is easy because the SPA Technique kit includes everything you'll need for an easy and safe installation. A completely filled SFI 17.1 certified and labeled bottle is included, as are the two stainless steel retaining straps. For discharge, the single six-foot pull cable is usually more than enough to let you put the bottle where you and your crew chief want it. This complete fire system also includes two nozzles, one T- fitting, one bulkhead fitting, and ten feet of 5/16" easy-to-install aluminum tubing. There's even a new "E" decal to make the tech inspectors happy.
SPA Technique fire systems are the perfect choice for drivers who demand the very best in SFI 17.1 certified fire safety.
This pressurized fire system can only be shipped via Ground.
SPA Extreme Novec SFI Fire System 5lb Details:
Manufacturer: SPA Technique
Manufacturer part number: EX-SFI5
Certification: SFI 17.1
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
Bottle Height: 13.75"
Bottle Dia: 4.25"
SPA Extreme Novec SFI Fire System 5lb Contents:
Five-lb. bottle, filled and pressurized
Retaining Straps x 2
Pull Cable, six feet
Discharge Nozzles x 2
T-Fitting
Bulkhead Fitting
5/16" Aluminum Tubing, ten feet
E-Sticker
SPA Technique
SPA SFI 17.2 SPA 4F SFI3-M FireSense+ 3lb. Mechanical Fire System
$533.00
SPA 17.2 SPA 4F SFI3-M FireSense+ 3lb. Mechanical Fire System
New SFI 17.2 Certified System with a New 4Fire Universal
SPA Technique SFI 17.2 certified 3-lbs. mechanically discharged complete fire system that comes out as a foam as opposed to a gas for a wider range of fire suppression applications. With complete coverage for three zones (one cockpit and two engine), the SPA 4F SFI-3-M system is a compact SFI 17.2 certified fire system.
Uniquely Effective and Versatile Fire Suppression
Branded as FireSense+, 4Fire Universal is a unique and effective fire suppression agent. It presents as a foam coating everything it hits, which helps to prevent re-ignition and cools at the same time. 4Fire Universal has quick fire-out times like a gas system, and is non-conductive to 1,000 volts like SPA Technique gas systems.
Where 4Fire Universal sets itself apart from other two agents is in its effectiveness extinguishing lithium battery fires.
This pressurized fire system can only be shipped via Ground.
SPA 17.2 SPA 4F SFI3-M FireSense+ 3lb. Mechanical Fire System Details:
Manufacturer: SPA Technique
Manufacturer part number: 4F-SFI3-M
Discharge: Six-foot mechanical cable
Certification: SFI 17.2
Agent: 4Fire
Toxic: No
Conductive: Non-conductive up to 1000V
SPA 17.2 SPA 4F SFI3-M FireSense+ 3lb. Mechanical Fire System Contents:
(1) Cockpit nozzle
(2) Engine bay nozzles
10 ft of 5/16" aluminum tubing
(2) 5/16" T-fittings
(1) 5/16" bulkhead fitting
(1) 6 ft pull-cable
(1) E sticker
(2) Bottle mounts
SPA Technique
SPA Extreme Novec FIA Fire System Spare Bottle - 2.25kg Mechanical
$475.00
SPA Extreme Novec FIA Fire System Spare Bottle (2.25kg Mechanical)
This is the spare bottle for SPA Technique's lightweight, mechanically-discharged 3M Novec 1230 fire system. This system has an FIA EX.049.18 rating while keeping weight to a minimum for lightweight race cars that still need the ultimate in fire protection.
The SPA Technique Extreme Novec 1230 is an FIA EX.049.18 certified fire system, the next generation of race car fire suppression. 3M Novec 1230 is not only safer for the driver, but also for the environment. And it's non-conductive (i.e., safe for electronics) while leaving no residue to clean up. If you want the safest race car fire system, the SPA Technique Extreme Novec systems are your first choice.
This is the spare bottle only. For the complete SPA Technique fire system, click here. SPA Technique fire systems are the perfect choice for drivers who want the best in FIA EX.049.18 certified fire safety.
This pressurized fire bottle can only be shipped via ground.
SPA Extreme Novec FIA Fire Bottle (2.25kg Mechanical) Details
Manufacturer: SPA Technique
Manufacturer part number: EX2.25-M B
Certification: FIA EX.049.18
Agent: 3M Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
Advantages of 3M Novec 1230 Fluid
Great fire-out properties
Non-toxic, so it is safe for driver, crew, and safety workers
Non-conductive, so it's safe for all in-car electronics
No residue or clean-up
Zero ozone depletion, making it safer for the environment
SPA Technique
SPA Extreme Novec SFI Spare Fire Bottle 5lb
$363.00
Spa Extreme Novec SFI 17.1 Fire System 5lb Spare Bottle
SPA Technique Extreme Novec 1230 5LB SFI 17.1 certified spare bottle is a complete, ready-to-install, filled and charged 5-lbs. aluminum spare bottle with a mechanical lever valve.
SPA Extreme Novec SFI 17.1 Spare Bottle 5lb Details:
Manufacturer: SPA Technique
Manufacturer part number: EX-SFI5-B
Certification: SFI 17.1
Agent: Novec 1230
Toxic: No
Conductive: No
Clean-up required: No
Bottle height: 13.75"
Bottle diameter: 4.25"
3M Novec 1230 is not only safer for drivers and crew, but also safer for the environment. It's also non-conductive (i.e., safe for electronics) and leaves no residue to clean up.
SPA Technique fire systems are the perfect choice for drivers that want the best in SFI 17.1 certified fire safety.
This pressurized fire bottle can only be shipped via Ground.
SPA Technique
SPA AFFF Fire System 2.25 Liter Alloy Mechanical
$290.00
Spa AFFF Fire System - 2.25 Liter Alloy Mechanical
This system is not SFI or FIA Certified. It will not pass ChampCar 2020 Tech.
This Kit is an Ideal Entry-Level System Offering Two Zone Protection that is aimed primarily at the clubmans, fast road and track day participant. These systems contain 2.25 Liters of AFFF (Aqueous Film Forming Foam) and are subject to the same level of rigorous testing as our high end systems.
All systems include nozzles, line, fittings, pull handles, and mounting hardware. So you get everything you need for a safe, clean installation.
SPA AFFF Fire System 2.25 Liter Alloy Details:
Manufacturer: SPA Technique
Manufacturer's part number: HPC-225
Bottle dimensions: 17.3" H x 4.3" DIA
SPA AFFF Fire System Kit Includes:
(1) Bottle filled and pressurized with 2.25kg of 4Fire
(2) Nozzles
(1) T-fitting
(2) Pull cables (one 6 feet, one 12 feet)
(2) E-stickers (one large, one small)
10ft of 8mm Dekabon tubing